Instruments

Q-Exactive Plus (ThermoFisher) high-resolution mass spectrometer (HRMS)

Q-Exactive Plus (ThermoFisher) high-resolution mass spectrometer (HRMS)

Advanced hybrid quadrupole-Orbitrap mass spectrometer with high resolution up to 280,000, fast scan speed, and HCD fragmentation. This HRMS system can be coupled either to UHPLC or to direct infusion for metabolomic applications such as detection, identification, and quantification of small molecules, metabolites, and lipids (Services).

This system is especially good for untargeted analysis of metabolites and lipids in the discovery phase.

Vanquish UHPLC system (ThermoFisher)

Vanquish UHPLC system (ThermoFisher)

Advanced high pressure and performance liquid chromatography system for separation of small molecules, metabolites, and lipids, used in combination with HRMS.

TriVersa NanoMate (Advion)

TriVersa NanoMate (Advion)

NanoChip-based electrospray ionization technology which combines LC, chip-based infusion, fraction collection, and direct surface analysis with the mass spec (Q-exactive plus) into one integrated system. It improves the high throughput and sensitivity of the analysis.

Triple Quadrupole with and Ion Trap (QTRAP 6500+ from Sciex)

Triple Quadrupole with and Ion Trap (QTRAP 6500+ from Sciex)
(Advanced mass-spectrometer with built-in triple quadrupole and q-trap capabilities)

This instrument has fast scan speeds for high-throughput analysis with millisecond polarity switching. This mass spectrometer has several targeted capabilities including multiple reaction monitoring (MRM) for quantitation of metabolites and lipids), constant neutral loss (CNL), and a precursor and product ion scans. This mass spectrometer also has MS3 capabilities for the qualitative analysis of metabolites and lipids.

The QTRAP system in the facility instrument can be coupled to either an LC (Exion) and to a differential ion mobility spectrometry (DMS) device.

This instrument is particularly good for hypothesis-driven studies, for analysis of low concentration metabolites, and, for metabolite quantitation.

XFe Extracellular Flux Analyzer (Seahorse)

Extracellular Flux Analyzers simultaneously interrogate the two major energy-producing pathways of the cell mitochondrial respiration and glycolysis in a microplate, in real-time.

Differential Mobility Separation device (DMS; Selexion from Sciex)

The DMS is used for separating isomers and isobars that are difficult to distinguish using LC and MS alone. It is also used for reducing chemical background noise thus improving limits of detection and thereby enhancing the sensitivity of the mass spectrometer.

Mode of operation: The DMS cell separates metabolites and lipids ions in the gas phase. DMS consists of two parallel electrode plates and it separates the ions using an asymmetrical RF field -alternating between high and low fields in opposite polarities - applied to the two plates. Ions are carried through the plates by a carrier gas. The separation of the ions can be enhanced using a volatile chemical modifier (e.g. methanol, isopropanol).

The DMS in our facility is used with a direct infusion into an MS (high-throughput analysis), or it can be coupled to both the LC and MS (LC-DMS/MS) to provide orthogonal separations and for analysis of complex samples.

EMBL MCF spectral library

LC-MS/MS spectral library from over 700 metabolite standards, available online.

Software

Thermo Xcalibur 3.0.63

Progenesis QI

Analyst software

Sciex OS